Skip to content
← Home
Environment1 min read

Active Living Walls Scrub Indoor Carbon Dioxide

Researchers modeled an architectural living wall system using hydroponic plants to absorb carbon dioxide in indoor spaces. This approach matters because people spend most of their time indoors where carbon dioxide accumulates far above outdoor levels.

Reviewed by

An architectural living wall featuring hydroponic plants and integrated mechanical fans inside an indoor space.
AI-generated illustration
Peer reviewed
Yes
Sample size
336 cubic meters

Key numbers

  • 90%

    human exposure to air pollution occurs indoors

  • 10times

    indoor gas concentrations compared to outdoor levels

  • 700 to 1,000parts per million

    CO2 concentrations affecting human health and cognition over extended periods

  • 428parts per million

    typical outdoor CO2 concentrations in the United States

  • 700parts per million

    threshold exceeded in urban residences and offices during afternoon and nighttime

  • 2070year

    when outdoor CO2 concentrations could exceed the threshold

  • 1,200parts per million

    indoor levels climbing beyond this limit

  • 39%

    more CO2 removed when airflow was directed from roots to leaves

Evidence level: Simulation or model

Why it matters: Prolonged exposure to elevated indoor carbon dioxide can affect human cognitive performance and physiological health, while standard heating, ventilation, and air-conditioning systems dilute indoor CO2 by bringing in outside air rather than actively removing it. As outdoor atmospheric CO2 rises, conventional HVAC systems cannot reduce indoor concentrations below outdoor levels. The Active Modular Phytoremediation System explores whether engineered living walls can actively remove indoor CO2 through photosynthesis, potentially helping buildings maintain healthier air as atmospheric concentrations increase.

How botanical modules process indoor air The Active Modular Phytoremediation System uses hydroponic vegetation inside interconnected architectural modules equipped with mechanical fans that move air through plant foliage and growth substrate. Each module contains three plant species: golden pothos, wood sorrel, and Saint John’s wort.

The system uses photosynthesis, the process by which plants convert sunlight, water, and CO2 into chemical energy, to remove CO2 from indoor air and release oxygen. The modules are arranged as a living wall, integrating vegetation with mechanical airflow rather than relying on passive plant placement.

Researchers tested the system in a tightly controlled environmental seal chamber at the Yale Science Building. They varied airflow direction, light intensity, growing medium, and lighting conditions, then measured differences in CO2 levels entering and exiting each module.

Directing air from the plant roots toward the leaves removed nearly 39% more CO2 than directing it from leaves to roots under comparable lighting conditions. The researchers suggest this may reflect interactions between leaf photosynthesis and root-associated microbial metabolism, although the exact mechanisms require further investigation.

Evaluating architectural living walls The study used real-world data from an occupied 336-cubic-meter laboratory space to run simulations testing different module numbers, configurations, airflow directions, and lighting conditions. These simulations modeled how the system could affect indoor CO2 concentrations under varied conditions.

Depending on airflow direction and lighting, the simulations estimated that between 95 and 3,653 modules could be required to offset indoor CO2 emissions. At peak performance, with airflow and lighting optimally calibrated, at least 363 modules were needed to reduce indoor CO2 concentrations to levels consistent with or lower than outdoor concentrations.

Tuning lighting and airflow direction produced a 43-fold improvement in the system’s CO2 remediation capacity. This result shows that performance depends heavily on engineering design, not simply on the presence of plants.

System condition Estimated module requirement Varying airflow and lighting conditions 95 to 3,653 modules. Optimized airflow and lighting At least 363 modules. Airflow from roots to leaves versus leaves to roots Nearly 39% more CO2 removed with root-to-leaf airflow. Tuned lighting and airflow direction 43-fold improvement in remediation capacity. Why HVAC systems cannot match this Typical HVAC systems dilute indoor CO2 by drawing in outdoor air. This means they cannot reduce indoor concentrations below the level occurring outside.

The AMPS approach uses photosynthesis to actively remove CO2 from indoor air. In some simulated iterations, the researchers created pockets of air with CO2 levels lower than outdoor concentrations, something most conventional HVAC systems cannot accomplish.

This distinction is important: the living wall is not simply another source of ventilation. It is an active biological removal system that, under optimized conditions, can reduce indoor CO2 below outdoor levels.

What remains unknown about deployment The study does not specify the financial cost of installing and maintaining 363 modules in everyday buildings. It also does not provide a timeline for commercializing the Active Modular Phytoremediation System.

The precise microbiological mechanisms linking root-associated metabolism and leaf photosynthesis remain unclear. Further research is needed to understand why root-to-leaf airflow improves CO2 removal and how these interactions vary across plant species, growing conditions, and building environments.

The findings rely on controlled chamber experiments and simulations based on an occupied laboratory space. They do not establish performance in typical homes, offices, schools, or other real-world buildings with varying occupancy, lighting, humidity, temperature, and ventilation conditions.

What the simulated living wall modules do not prove It may seem that ordinary indoor potted plants are already sufficient to clean indoor carbon dioxide down to outdoor levels. In fact: achieving this reduction requires a specific engineered system with mechanical fans, optimized root-to-leaf airflow, and precisely tuned lighting configurations.

It may seem that the 363-module estimate applies to every building. In fact: it applies to a 336-cubic-meter laboratory space under optimized conditions; module requirements varied from 95 to 3,653 depending on airflow and lighting.

It may seem that the system is ready for commercial deployment. In fact: the study does not report installation and maintenance costs, commercialization timelines, or real-world building performance.

It may seem that the root-to-leaf airflow result is fully understood. In fact: the researchers identify a likely relationship between leaf photosynthesis and root-associated microbial metabolism, but say the exact mechanisms require further investigation.

Verdict: Simulations based on an occupied 336-cubic-meter laboratory space demonstrated that an optimized arrangement of at least 363 living-wall modules could reduce indoor CO2 concentrations to levels consistent with or lower than outdoor levels. The system’s performance depended strongly on airflow direction and lighting, with root-to-leaf airflow removing nearly 39% more CO2 than the reverse direction. However, the findings rely on controlled chamber tests and computer simulations, leaving practical deployment costs, commercial timelines, and real-world building performance unaddressed.


Based on reporting from Yale News. This is an independent explainer, written in our own words with AI assistance; Yale News has not reviewed or endorsed it. Read the original for the full details.

Share